Cannot View Concurrent Manager Log And Out Files in R12

$
0
0

Error:

'APP-FND-1634-The log file &FILENAME does not exist or this program is restricted from reading it'

If the concurrent request has completed then please contact your system administrator.

APP-FND-1636 NO REPORT AVAILABLE FOR THIS CONCURRENT PROCESS

Cause:

Profile Option 'RRA:enabled' setting is not correct.

Solution:

To implement the solution, please execute the following steps:

1. Shut down managers and verify no FNDLIBR processes are running.
2. Go into the responsibility: System Administrator
3. Navigate to profile/system
4. Search for profile 'RRA:enabled' and set the value to Yes.
5. Save
6. Restart the managers
7. Retest the issue.